Allmand Trucking Equipment For Sale
Shop Allmand trucking equipment including portable light towers with diesel power, towable design, generator output, and jobsite-ready lighting.
Learn moreHave allmand trucking equipment to sell? List it here to reach thousands of buyers.
About Allmand Trucking Equipment
The big buying decisions usually come down to engine make, generator output, mast and light package, and the condition of the trailer chassis. Many Allmand units use small 3-cylinder diesel engines from Kubota, Kohler, or Caterpillar. Common generator sizes in this class are around 6 kW to 7.5 kW, with 120V or 120/240V receptacle capability depending on the model and setup. On older units, verify that the generator side actually carries load and that receptacles, breakers, and voltage regulation are working as intended. Light output is commonly configured through four fixtures, often in the 1,000W to 1,250W range on metal halide systems, so buyers should inspect ballast condition, fixture housings, mast rotation, winch function, and cable integrity.
Trailer details matter more than many first-time buyers expect. Check tire size and age, wheel bearings, steel wheels, coupler style, safety chains, lighting harness, outriggers or leveling jacks, and any damage around the tongue. Many units in this category are equipped with a pintle hook eye, trailer ball coupler, or a convertible towing arrangement, so match the coupler setup to the truck that will move it. Weight in this class is often under 2,000 pounds, which helps with transport flexibility, but stability on uneven ground depends heavily on the condition of the leveling system. If the light tower will be used daily, mast lock points, jack stands, and frame integrity deserve close attention.
Used Allmand equipment is often purchased on operating condition more than appearance, but hours still matter. A unit with 3,000 to 6,000 hours can remain useful if it starts cleanly, runs at proper RPM under load, holds voltage, and raises and lowers the mast without binding. Look for maintenance records, fuel system condition, battery health, and signs of water intrusion in the control box. For contractors, municipalities, and fleet buyers, Allmand towable light towers remain a practical equipment class because they combine mobility, diesel efficiency, compact dimensions, and dependable nighttime illumination in one trailer-ready package.
Frequently Asked Questions
What kind of Allmand trucking equipment is most common on the used market?
The most common Allmand units found in trucking and contractor equipment listings are portable light towers, also called towable light plants. Models such as the Night-Lite Pro and Night-Lite Pro II are built to provide jobsite lighting and generator power in a compact trailer-mounted platform. They are commonly used for highway work, utility repairs, construction staging, and emergency service operations where crews need reliable lighting that can be moved quickly between locations.
What should I inspect first on a used Allmand light tower?
Start with the engine, generator, mast system, and trailer running gear. Confirm the diesel engine starts easily, runs smoothly, and does not smoke excessively. Test the generator under load, not just at idle, and verify all receptacles and breakers function properly. Raise and lower the mast, rotate the light assembly if equipped, and inspect fixtures, wiring, and winch components. On the trailer side, check the coupler, tires, wheel bearings, safety chains, frame condition, and leveling jacks because these items directly affect transport safety and setup stability.
Are Allmand light towers usually diesel powered?
Yes, many Allmand light towers use small diesel engines, often 3-cylinder designs from manufacturers such as Kubota, Kohler, or Caterpillar depending on model year and configuration. Diesel power is preferred in this equipment class because it offers good runtime, fuel efficiency, and dependable torque for generator operation. Engine brand matters less than overall condition, service history, and the unit's ability to maintain proper speed and electrical output under working load.
How much generator capacity do Allmand towable light towers usually have?
Many Allmand units in this class are equipped with generators in the 6 kW to 7.5 kW range. That output is typically enough to run the onboard lighting system and provide auxiliary jobsite power through 120V or 120/240V receptacles, depending on the unit. Buyers should verify actual voltage output and load performance because older used light towers may have engine systems that run well while the generator side has faults in the alternator, regulator, wiring, or receptacles.
Do hours matter on a used Allmand Night-Lite tower?
Hours matter, but condition matters more. A higher-hour unit can still be a strong value if it has been maintained properly, produces correct generator output, and has a mast and trailer chassis in solid working order. Lower hours are attractive, but they should not outweigh poor maintenance, electrical issues, neglected tires, or damaged outriggers. The best approach is to treat hours as one part of the evaluation alongside startup behavior, load testing, structural condition, and service records.